Processor |
|
CPU |
32-bit Freescale ColdFire® Microprocessor |
Memory |
|
SDRAM |
64 MB |
|
NVRAM |
256 KB |
|
Flash |
4 MB |
|
Compact Flash |
expandable up to 4 GB (not included) |
Operating System |
|
Real-time, preemptive multi-threaded/multitasking kernel; FAT32 file system with long names; supports SIMPL™ Windows® and SIMPL+® |
Ethernet |
|
With C2ENET-1 |
10/100BaseT, auto-negotiating, full/half duplex, static IP or DHCP/DNS, SSL, TCP/IP, UDP/IP, CIP, SMTP, SNMP, built-in Web server and e-mail client; supports Crestron e-Control®2 XPanel and RoomView™ applications |
|
With C2ENET-2 |
All above features plus: built-in firewall, router, and network address translator (NAT) |
Y-Bus Connectors & Expansion Slots |
|
40 Mb/s parallel communications;
Internal backplane for integrated control ports and Y-Bus expansion slots |
|
I/O 1 - 8 |
(1) 9-pin 3.5mm detachable terminal block comprising (8) “Versiports” – digital input/output or analog input ports;
Digital Input: Rated for 0-24 Volts DC; input impedance 20k ohms; logic threshold 1.24 Volts DC;
Digital Output: 250 mA sink from maximum 24 Volts DC; catch diodes for use with “real world” loads;
Analog Input: Rated for 0-10 Volts DC, protected to 24 Volts DC maximum; input impedance 20k ohms;
Programmable 5 Volts, 2k ohms pull-up resistor per pin;
All ports referenced to ground |
|
RELAY OUTPUT 1 - 8 |
(2) 8-pin 3.5mm detachable terminal blocks comprising (8) normally open, isolated relays;
Rated 1 Amp, 30 Volts AC/DC;
MOV arc suppression across contacts |
|
S1, S2 |
(2) Y-Bus expansion slots;
Accept all Y-Bus control cards |
Z-Bus Expansion Slots |
|
300 Mb/s parallel communications;
Backplane for Z-Bus expansion slots |
|
S-3 Z-BUS |
(1) Z-Bus expansion slot;
Accepts all Z-Bus control cards |
Additional Connectors |
|
LEFT, RIGHT |
(2) 5-pin 0.156 inch headers;
Module interconnect ports, connect to CLX-Series lighting control modules using interconnect cables provided |
|
Cresnet Hub/Repeater |
Cresnet data and power distribution:
NET A – H: (32) 4-pin 3.5mm detachable terminal blocks comprising (4) Cresnet ports (paralleled) per each of (8) segments
POWER 1 – 4: (4) 3-pin 3.5mm detachable terminal blocks comprising (1) Cresnet power selection connector per each of (4) power groups;
Connect to external Cresnet power supply, or to internal power supply via jumpers, to power Cresnet devices connected to the NET ports;
Maximum Load per Power Group using external supply: 75 Watts (3.125 Amps @ 24 Volts DC);
Maximum Total Load using internal supply: 50 Watts (2 Amps @ 24 Volts DC)
|
|
OVERRIDE |
(1) 3-pin 3.5mm detachable terminal block comprising (2) inputs from external contact closures to trigger the preset Override state in CLX-Series modules connected to the module interconnect ports;
Maximum Input: 10mA at 5 Volts |
|
BACKUP NET INPUT |
(1) 4-pin 3.5mm detachable terminal block
Backup Cresnet port;
Connects to the NET port of a backup control system and power supply |
|
FAULT |
(1) 2-pin 3.5mm detachable terminal block;
Contact closure output;
Relay closed when PAC2 becomes inactive;
Connects to digital input of backup control system |
|
NET |
(1) 4-pin 5mm detachable terminal block;
Cresnet port, Master/Slave selectable;
Expandable via C2N-NPA8 Network Poll Accelerator |
|
COMPUTER |
(2) DB9 female;
RS-232 computer console port |
|
Line Power |
(1) Attached input power cable (~1 ft long) with inline IEC320 socket;
Connects to AC power source using grounded pigtail cable and DIN rail terminal block (both included) |
Reset Buttons |
|
HW-R |
Hardware reset (reboots the control system) |
|
SW-R |
Software reset (restarts the SIMPL program) |
LED Indicators |
|
NET A – H |
(yellow x8) Indicate Cresnet communications on each respective segment |
|
POWER 1 – 4 |
(green x4) Indicate 24 Volts DC power present at each respective power group |
|
PWR |
(green) Indicates power supplied to unit via AC line or BACKUP NET INPUT |
|
NET |
(yellow) Indicates Cresnet bus activity |
|
MSG |
(red) Indicates control system has generated an error message |
|
LNK A |
(red) Indicates a valid connection on LAN port A |
|
ACT A |
(red) Indicates activity on LAN port A |
|
LNK B |
(red) Indicates a valid connection on LAN port B |
|
ACT B |
(red) Indicates activity on LAN port B |
|
FAULT |
(red) Indicates PAC2 has become inactive, FAULT output is active (relay closed) |
Power Requirements |
|
Main Power Consumption |
2.4 Amps, 100-250 Volts AC, 50/60 Hz |
|
Available Cresnet Power |
50 Watts (shared with control card expansion slots) |
Environmental |
|
Temperature |
41° to 113°F (5° to 45°C) |
|
Humidity |
10% to 90% RH (non-condensing) |
Enclosure |
|
Black and gray metal, surface mount box with (2) integral mounting flanges;
Occupies 1 module space in a single-width CAEN or CAENIB enclosure, or 2 side-by-side module spaces in a double-width enclosure |
Dimensions |
|
Height |
8.00 in (20.32 cm) |
|
Width |
14.00 in (35.56 cm) |
|
Depth |
3.75 in (9.52 cm) |
Weight |
|
8.0 lb (3.62 kg) – with line cord |